ElectricSubmeter.com - Your Electical Submetering Specialists

Click for TestEquipmentDepot.com
Home E-Mon D-Mon National Meter Test Equipment Depot Ordering/Contact Info

 

<< National Meters kWh Meters

National Meter Industries K4000 & KW4000 Series
Three Phase Kilowatt Hour Energy Meters, Discontinued
Models K4240, K4480, KW4240, KW4480

See: E-Mon D-Mon Three-Phase Electric Submeters:


  • Six-Digit kWh LCD Display (No Display Multipliers)
  • Displays L1, L2 & L3 Power Readings, Volts, Amps and Instantaneous KW
  • KW4240 and KW4480 Also Display Maximum KW Demand Readings
  • Remote CT Operated
  • kWh Pulse, Form A Relay
  • Plug in Terminals for Field Testing
  • Display Indicates Correct Wiring
  • Includes Three LX-400 4-400A Solid Core Current Transformers
    (Split Core and Solid Core CT's up to 10 KW Optional)
  • Easy to Install

Applications:

  • Industrial
  • Commercial
  • OEM

K4240 and K4480 kWh Meters

Series 4000 (K4000) kWh meters are factory programmed, offering one model for both 3 or 4 wire feeder or branch circuits. This meter will also display voltage, amperage and real KW.

KW4240 and KW4480 kWh and KW Demand Meters

Series 4000 (KW4000) kWhr and KW Demand Meters will display kWhs, Maximum KW Demand as well as instantaneous kilowatts. The kW Demand reading will scroll with the kWh Display. The demand interval is factory set at 15 minutes unless otherwise instructed. Sliding or Rolling Window is the demand method used by the meter. Either one of these models field wire exactly alike.

    
Click here for larger image   Click here for larger image
Front   Kit
KW4240 Shown
 
Click here for larger image
LX400 CT, 3 Included
     
Product Information
Manual 567 KB
Specifications HTMLHTML Content on This Page, Click Link to Jump to
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
PDF Help
 

Connection Diagrams

Click here for larger image
3 Phase,
3 Wire

Click here for larger image
3 Phase,
4 Wire, Hi-Leg

 

Series 4000 Three Phase Kilowatt Hour Energy Meters (All Models)

There are six (6) digits across the top section of the display. These digits represent kilowatt-hours (energy) consumed. There are no display multipliers needed to read the energy consumed. There are three additional readings in the middle of the display. These readings are three digits of voltage, three digits of Amperage and three digits of instantaneous kilowatts. These power readings will display "HI" when the readings exceed 3 digits, i.e.: 1000 AMPs or kW.

The factory programs Relay 1 to 1 kWhr per pulse, as a standard, unless otherwise instructed. 

There is a RS485 Modbus terminal next to the relay. This port works with our Intelligent Converter that plugs into the RS232 comm. port in the PC. NMI offers several software programs. Call for more information.

The voltage and the current terminals are removable. If a field calibration check is necessary the terminals simply unplug and a portable 'Meter Standard' can plug into them. (have technician get a set of female plugs from factory). These terminals are a standard feature on all of our meters. Also, there are two rows of CT terminals used when paralleling two sets of CTs. Remember Current Sensors with voltage outputs cannot be paralleled. Voltage is not additive, where current is.

There are holes in each corner of the meter for mounting the meter against a plywood board, sheet rock wall or switch boards. We do not recommend that the meters be mounted against a concrete wall.

 
Specifications
Enclosure NEMA 1. ABS Plastic
Temp Range: -10 to 120 Degree F
Humidity: 95% Non-condensing
Reed Relay: (240v-10amps) AC/DC
Meter Instrumentation: 0.635 amps
Burden: CT Burden 0.06 VA
C.T. Circuit Isolated
Power Source Non-Volatile Memory
KW Demand Models KW4240 and KW4480 only
Compliance
Accuracy: Meters - ANSI C12.16
C.T. - ANSI C57.1
FCC: Class A Part 15
UL: 61010B-1, CUL, EC
Location-Based Compliance Michigan Compliant
NYC Approved
 
Ordering Information
Model Description Buy Price
K4240 National Meter K4240 120 / 208 / 240V Three Phase 3 or 4 wire kWh Meter, including Hi Leg System  Discontinued
See: E-Mon D-Mon 3-Phase Submeters
KW4240 National Meter KW4240 120 / 208 / 240V Three Phase 3 or 4 wire kWh and KW Demand Meter, Including Hi Leg System Discontinued
See: E-Mon D-Mon 3-Phase Submeters
K4480 National Meter K4480 277 / 480V Three Phase 3 or 4 wire kWh Meter Discontinued
See: E-Mon D-Mon 3-Phase Submeters
KW4480 National Meter KW4480 277 / 480V Three Phase 3 or 4 Wire kWh and KW Demand Meter Discontinued
See: E-Mon D-Mon 3-Phase Submeters
Included Accessories
 
  • 1 - Instruction Manual
  • 1 - RS485 Output ModBus RTU & 1 Output Relay
  • 3 - LX-400Click for Product ImageSolid Core Current Transformers (4 to 400 amp range)
Included
Current Transformers
LX Series Solid Core and Higher Rating (>400 A) Current Transformers  
TP Series Split Core and Higher Rating (>400 A) Current Transformers  
Software
NMIRBP NMI Reading and Billing Program Please Call
NMIPSP Power Studio Program Please Call


National Meter Catalog | National Meter Pricelist


Home  |  E-Mon  |  National Meter Test Equipment Depot  |  Ordering/Contact Info

$25.00 Minimum on Total Order


____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email: